Analyses Reach
4,4-Méthylènedianiline
Dosage de la 4,4-Méthylènedianiline (amine durcisseur contenue dans la liste des amines en restriction)
|
|
Standard: | ISO 17234 et EN 14362-1 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Alkylphénols
Dosage des alkylphénols et de leurs éthoxylates |
|
Standard: | ISO 18218-1 et extraction interne |
Equipment: | Shimadzu HPLC Nexera |
Certification: | No |
Sectors: | Watchmaking, Jewelry, Leather goods, Packaging / Displays |
Anthracène
Dosage de l’Anthracène (SVHC, REACH)
|
|
Standard: | AfPS GS 2014:01 PAK |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Horlogerie, Métallurgie, Bijouterie, Maroquinerie, Packaging / display, Médical |
Base et cétone de Michler (BM et CM)
Dosage des BM et CM (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Chrome VI
Dosage du chrome VI dans les cuirs |
|
Standard: | EN ISO 17075-1 |
Equipment: | Shimadzu UV-2600 |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Colorants azoïques / amines aromatiques
Dosage des amines aromatiques en restriction découlant de la coupure réductrice de colorants azoïques (REACH) |
|
Standard: | ISO 17234, EN 14362-1 et EN 14362-3 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Fluorine compounds
Detection of fluorinated compounds (SVHC, REACH)
|
|
Standard: | CEN/TS 15968 |
Equipment: | Shimadzu HPLC Nexera |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
DMF (N,N-Diméthylformamide)
Dosage du DMF (SVHC REACH)
|
|
Standard: | ISO 16189 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Watchmaking, Jewelry, Leather goods, Packaging / Display, Medical, Telephony |
DMFu (Diméthylfumarate)
Dosage du DMFu (Annexe XVII REACH)
|
|
Standard: | ISO 16186 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Formamide
Dosage du Formamide (SVHC, REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra et Shimadzu GC-MS QP2010 Ultra + HS20 |
Certification: | No |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
HAP (Hydrocarbures Aromatiques Polycycliques)
Dosage of PAHs according to US-EPA and Annex XVII, REACH |
|
Standard: | AfPS GS 2014:01 PAK et ISO 18287 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
HBCDD (Hexabromocyclododécane)
Dosage du HBCDD – tous les isomères (Annexe XIV REACH)
|
|
Standard: | ISO 17881-1 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Imidazolidine-2-thione
Dosage de l’Imidazolidine-2-thione (accélérateur de vulcanisation, SVHC, REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | No |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Libération de nickel
Dosage de la quantité de nickel libérée par semaine et par unité de surface dans de la sueur synthétique (Annexe XVII, REACH), avec ou sans usure préalable selon EN 12472
|
|
Standard: | EN 1811 et EN 12472 |
Equipment: | Shimadzu ICPE-9000 |
Certification: | Yes |
Sectors: | Telephony, Medical, Jewelry, Watchmaking, Metalworking |
Métaux et leurs sels
Dosage des métaux (SVHC, RoHS 2 et California Proposition 65) |
|
Standard: | EN 62321, ISO 17072-2, EN 10351 et EPA Method 3052B |
Equipment: | Shimadzu ICPE-9000 |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking, Telephony |
NMP (N-méthyl-2-pyrrolidone)
Dosage NMP (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Organotin chemistry
Dosage of organotins (Japanese law 112, REACH and ORRChim) |
|
Standard: | ISO/TS 16179 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
Phthalates
Dosage of phthalates (SVHC, CPSA) |
|
Standard: | ISO/TS 16181 (cuir/caoutchouc) et ISO 14389 (textile) |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
PTOP (p-tert-Octylphénol ou 4-tert-Octylphénol)(H315)
Dosage du PTOP (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking |
Screening REACH
Screening permettant de détecter les SVHC (REACH) contenus dans les articles |
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 |
Certification: | No |
Sectors: | Watchmaking, Jewelry, Leather goods, Packaging / Display, Medical, Telephony |
TCEP (Tris(2-chloroéthyl)phosphate)
Dosage du TCEP (SVHC, REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Packaging / Display, Leather goods, Jewelry, Watchmaking |
TGIC et beta-TGIC (Triglycidyl isocyanurate)
Dosage du TGIC et beta-TGIC (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
2-MBT (2-Mercaptobenzothiazole)
Dosage du 2-MBT
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
4,4-Méthylènedianiline
Dosage de la 4,4-Méthylènedianiline (amine durcisseur contenue dans la liste des amines en restriction)
|
|
Standard: | ISO 17234 et EN 14362-1 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Alkylphénols
Dosage des alkylphénols et de leurs éthoxylates |
|
Standard: | ISO 18218-1 et extraction interne |
Equipment: | Shimadzu HPLC Nexera |
Certification: | No |
Sectors: | Watchmaking, Jewelry, Leather goods, Packaging / Displays |
ICP-OES Analysis
Dosage of metals by photon emission at its wavelengths (majority of the elements of the periodic table except rare gases, halogens (except I), actinides (except Th and U), H, C, N, O, Tc, Pm, Po , At, Fr, Ra) |
|
Equipment: | Shimadzu ICPE-9000 |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
GC-MS Analysis
Dosage of organic substances by column separation (GC) and characterization by mass spectrometer (MS) |
|
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Analyse par spectrométrie FTIR avec ATR (Silver gate et Ge)
Polymer characterization |
|
Equipment: | Shimadzu IRPrestige-21 |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
REACH & RoHS Analysis
Dosage of restricted or prohibited substances according to REACH and RoHS legislation, but also such as: Japanese law 112, California Proposition 65, ORRChim, US CPSA, GB China |
|
Standard: | Substance dependent |
Equipment: | Depends on substance |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Anthracène
Dosage de l’Anthracène (SVHC, REACH)
|
|
Standard: | AfPS GS 2014:01 PAK |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Horlogerie, Métallurgie, Bijouterie, Maroquinerie, Packaging / display, Médical |
Base et cétone de Michler (BM et CM)
Dosage des BM et CM (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Chlorophenols
Detection of chlorophenols (PCP, TriCP and TeCP (ORRChim)
|
|
Standard: | EN ISO 17070 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
Chrome soluble
Dosage du chrome total extractible |
|
Standard: | ISO 105-E04 |
Equipment: | Shimadzu ICPE-9000 |
Certification: | No |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Chrome VI
Dosage du chrome VI dans les cuirs |
|
Standard: | EN ISO 17075-1 |
Equipment: | Shimadzu UV-2600 |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Colorants allergènes et cancérigènes de dispersion
Dosage of allergenic or carcinogenic disperse dyes
|
|
Standard: | DIN 54231 |
Equipment: | Shimadzu HPLC Nexera |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking |
Colorants azoïques / amines aromatiques
Dosage des amines aromatiques en restriction découlant de la coupure réductrice de colorants azoïques (REACH) |
|
Standard: | ISO 17234, EN 14362-1 et EN 14362-3 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Fluorine compounds
Detection of fluorinated compounds (SVHC, REACH)
|
|
Standard: | CEN/TS 15968 |
Equipment: | Shimadzu HPLC Nexera |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
DMF (N,N-Diméthylformamide)
Dosage du DMF (SVHC REACH)
|
|
Standard: | ISO 16189 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Watchmaking, Jewelry, Leather goods, Packaging / Display, Medical, Telephony |
DMFu (Diméthylfumarate)
Dosage du DMFu (Annexe XVII REACH)
|
|
Standard: | ISO 16186 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
DMG (diméthylglyoxime)
Méthode de contrôle qualitative pour la libération du nickel par frottis |
|
Standard: | PR EN 12471 |
Equipment: | Kit DMG |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Dosage of elements in alloys
Dosage of alloying elements |
|
Standard: | NF EN 62321, EN 10351 & EPA Method 3052B |
Equipment: | Shimadzu ICPE-9000 |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
EGDMA (Ethylène glycol diméthacrylate)
Dosage de l’EGDMA (H317)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Formamide
Dosage du Formamide (SVHC, REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra et Shimadzu GC-MS QP2010 Ultra + HS20 |
Certification: | No |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Formaldehyde
Formaldehyde testing, Japanese Law 112 and California Proposition 65
|
|
Standard: | ISO 17226-1, ISO 17226-2 et ISO 14184-1 |
Equipment: | Shimadzu HPLC Nexera |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
HAP (Hydrocarbures Aromatiques Polycycliques)
Dosage of PAHs according to US-EPA and Annex XVII, REACH |
|
Standard: | AfPS GS 2014:01 PAK et ISO 18287 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
HBCDD (Hexabromocyclododécane)
Dosage du HBCDD – tous les isomères (Annexe XIV REACH)
|
|
Standard: | ISO 17881-1 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Huiles
Composition huiles de mouvement |
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | No |
Sectors: | Médical, Horlogerie |
Imidazolidine-2-thione
Dosage de l’Imidazolidine-2-thione (accélérateur de vulcanisation, SVHC, REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | No |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Isocyanates
Dosage of isocyanates (H317) |
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 |
Certification: | No |
Sectors: | Watchmaking, Jewelry |
Libération de nickel
Dosage de la quantité de nickel libérée par semaine et par unité de surface dans de la sueur synthétique (Annexe XVII, REACH), avec ou sans usure préalable selon EN 12472
|
|
Standard: | EN 1811 et EN 12472 |
Equipment: | Shimadzu ICPE-9000 |
Certification: | Yes |
Sectors: | Telephony, Medical, Jewelry, Watchmaking, Metalworking |
Métaux et leurs sels
Dosage des métaux (SVHC, RoHS 2 et California Proposition 65) |
|
Standard: | EN 62321, ISO 17072-2, EN 10351 et EPA Method 3052B |
Equipment: | Shimadzu ICPE-9000 |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking, Telephony |
NMP (N-méthyl-2-pyrrolidone)
Dosage NMP (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Organotin chemistry
Dosage of organotins (Japanese law 112, REACH and ORRChim) |
|
Standard: | ISO/TS 16179 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
para-Phénylènediamine (PPD) et N-Isopropyl-N’-phényl-p-phénylènediamine (IPPD))
Dosage de la PPD (colorant allergène contenu dans les plastiques/caoutchoucs)
|
|
Standard: | Norme interne et EN 14362-1 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | No |
Sectors: | Leather goods, Jewelry, Watchmaking |
PBB et PBDE (Polybromo biphényls et Polybromo diphényls éthers)
Dosage des PBB et PBDE (retardateurs de flammes, RoHS et REACH) |
|
Standard: | ISO 17881 et EN 62321 |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
PCCC (Paraffines chlorées à chaînes courtes, C10-C13)
Détermination de la présence de PCCC (polluants organiques) (Reg (EC) N° 850/2004, update N° 519/2012)
|
|
Standard: | ISO_DIS 18219 |
Equipment: | Shimadzu GC-MS-NCI QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
pH
Détermination de la valeur pH (degré d’acidité) |
|
Standard: | EN ISO 4045 (cuir) et ISO 3071 (textile) |
Equipment: | pH meter |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
Phthalates
Dosage of phthalates (SVHC, CPSA) |
|
Standard: | ISO/TS 16181 (cuir/caoutchouc) et ISO 14389 (textile) |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
PTBP (p-tert-Butylphénol)
Dosage du PTBP
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Leather goods, Jewelry, Watchmaking |
PTOP (p-tert-Octylphénol ou 4-tert-Octylphénol)(H315)
Dosage du PTOP (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking |
Screening allergène
Screening permettant de détecter les principaux allergènes contenus dans les articles. |
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 |
Certification: | No |
Sectors: | Medical, Watchmaking, Jewelry, Telephony |
Screening REACH
Screening permettant de détecter les SVHC (REACH) contenus dans les articles |
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 |
Certification: | No |
Sectors: | Watchmaking, Jewelry, Leather goods, Packaging / Display, Medical, Telephony |
Soufre et carbone
Dosage du soufre et du carbone |
|
Standard: | ISO 15350 |
Equipment: | Combustion avec détecteur infrarouge |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
UV stabilizers
Dosage of the following UV stabilizers:
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP 2010 Ultra |
Certification: | No |
Sectors: | Watchmaking, Jewelry, Packaging / Display |
TCEP (Tris(2-chloroéthyl)phosphate)
Dosage du TCEP (SVHC, REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Packaging / Display, Leather goods, Jewelry, Watchmaking |
TGIC et beta-TGIC (Triglycidyl isocyanurate)
Dosage du TGIC et beta-TGIC (SVHC REACH)
|
|
Standard: | Internal standard |
Equipment: | Shimadzu GC-MS QP2010 Ultra |
Certification: | Yes |
Sectors: | Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Vieillissement cuir avant analyse Cr VI
Leather aging before chromium VI analysis |
|
Standard: | ISO 17075-3 |
Equipment: | Steamroom |
Certification: | No |
Sectors: | Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking |
Tests de vieillissement climatique
REACH & RoHS Analysis
Dosage of restricted or prohibited substances according to REACH and RoHS legislation, but also such as: Japanese law 112, California Proposition 65, ORRChim, US CPSA, GB China |
|
Standard: | Substance dependent |
Equipment: | Depends on substance |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Salt spray
Corrosion Testing, Salt Spray Test |
|
Standard: | ISO 9227 & NIHS 96-50 |
Equipment: | Spray enclosure (alternating or continuous) |
Certification: | Yes |
Sectors: | Jewelry, Watchmaking, Metalworking |
Heat-humidity
Damp heat testing. |
|
Standard: | NIHS 96-50 & EN 60068-2-67 |
Equipment: | Climatic chambers ATT DY250 and ATT DY250+UV |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Thermal stress
Resistance test to cycles of exposure to 70°C then immersion in water at 5°C |
|
Standard: | NIHS 96-50 |
Equipment: | Oven at 70°C and refrigerator |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Metal contamination
Resistance test to oxidizable metals of surfaces |
|
Standard: | NIHS 96-50 |
Equipment: | Climatic chambers ATT DY250 and ATT DY250+UVH |
Certification: | No |
Sectors: | Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking |
Contrôle étanchéité/microfuites
Checks the tightness of the material up to 1000 m |
|
Standard: | ISO 6425 / ISO 22810 & NIHS 92-11 / 92-20 |
Equipment: | Roxer P30, mariot meter |
Certification: | Yes |
Sectors: | Watchmaking |
Climatic cycles of aging (cold – heat – humidity)
Resistance test to accelerated aging cycles (hot-cold alternation) |
|
Standard: | by NI (n.b. internal standard) |
Equipment: | Climatic chambers ATT DY250 and ATT DY250+UV |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Pool water
Corrosion resistance test by chlorinated agents |
|
Standard: | NIHS 96-50 |
Equipment: | Desiccator + oven |
Certification: | No |
Sectors: | Jewelry, Watchmaking, Metalworking |
Flower of Sulfur (or Thioacetamide)
Corrosion resistance test by sulfur agents (copper base materials, gold alloys, solder and galvanic coating) |
|
Standard: | NIHS 96-50 / ISO 12687 (ISO4538 Thio) |
Equipment: | Desiccator + oven |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Hydrolysis
Resistance test of elastomer seals to humidity saturation and at different temperatures depending on the type of polymers |
|
Standard: | Internal standard |
Equipment: | Autoclave |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Watchmaking |
Color migration in contact with water
Color migration test in water |
|
Standard: | Internal standard / ISO 105-A03 |
Equipment: | Crystallizer |
Certification: | No |
Sectors: | Leather goods, Jewelry, Watchmaking |
Color migration through sweat
Color migration test on blotter or sweat-soaked cotton |
|
Standard: | NIHS 96-11 / ISO 3260-2 |
Equipment: | Oven at 40°C |
Certification: | yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
Ozone for rubber
Ozone resistance test |
|
Standard: | ISO 1431-1 |
Certification: | No |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
Solar radiation / UV
Color resistance test to solar radiation |
|
Standard: | EN 60068-2-9, NIHS 96-50, ISO 105 A02, ISO 105 A03 et ISO 105 B02 |
Equipment: | Vötsch VCL 4033MH climatic chamber with metal halide |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Water drop resistance
Behavior of the coating in contact with a drop of water |
|
Standard: | ISO 105 A02-03 / IUF 420 / NIHS 96-50 |
Certification: | No |
Sectors: | Leather goods, Jewelry, Watchmaking |
Resistance to cosmetics
Resistance test to cosmetic products (perfume, sunscreen, body milk and mosquito repellent) |
|
Standard: | Internal standard / ISO 105-A02-3 / NIHS 96-50 |
Equipment: | Oven at 40°C |
Certification: | No |
Sectors: | Leather goods, Jewelry, Watchmaking |
Solvent resistance
Solvent resistance test by immersion (Ethyl acetate, acetone, isopropyl alcohol, benzene, ethanol or as requested) |
|
Standard: | NIHS 96-50 |
Equipment: | Crystallizer |
Certification: | No |
Sectors: | Leather goods, Jewelry, Watchmaking |
Synthetic sweats
Synthetic sweat corrosion resistance test |
|
Standard: | NIHS 96-50 & ISO 12870 |
Equipment: | Spray chamber or by contact in an oven |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
Tests de vieillissement mécanique
Pendulum sheep shocks
Application of a shock with an acceleration of between 500 and 5000 g |
|
Standard: | ISO 1413 & NIHS 91-10 |
Equipment: | Pendulum sheep |
Certification: | Yes |
Sectors: | Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking |
Chapuis shocks
Simulates the wear and aging of an assembly using shocks between 50 and 100 g |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
Screw tightening / loosening torque measurement
Measurement of the tightening / loosening torque of screws or other screwed elements |
|
Standard: | Internal standard |
Equipment: | Torque meter |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Force measurement
Standard: | Internal standard |
Equipment: | Mecmesin |
Certification: | No |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Measurement of the kinetic energy of glass breaking
Test the resistance of the glass using a falling ball |
|
Standard: | ISO 14368-3 / NIHS 61-13 |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Watchmaking, Telephony |
Torque measurement: crown rotation, crown function wear and crown seal
Torque measurement of a rotating bezel and screwed elements. Simulates the wear and aging of the rotational movement of the crown (with water resistance control) |
|
Standard: | Internal standard, NIHS 92-11 & ISO 6425 |
Equipment: | Torque meter |
Certification: | Yes |
Sectors: | Watchmaking |
Measurement and control of looseness, deflection and torsion angle of bracelets
Measurement of the different torsion angles of a metal bracelet (before and after aging) |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Jewelry, Watchmaking |
Pin and insert extraction force measurement
Measures the force to extract a pin or insert |
|
Standard: | Internal standard |
Equipment: | Mecmesin + JJTM 5000 |
Certification: | No |
Sectors: | Jewelry, Watchmaking |
Alternating wrist movements
Simulates the aging of the assembly elements by moving the bracelet back and forth |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Jewelry, Watchmaking |
Disorderly movements
Test the behavior of the assembly elements by applying a disordered movement |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Jewelry, Watchmaking |
Swivel clasp joints
Simulates the aging of the axes of the mobile blades of the clasp |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Jewelry, Watchmaking |
Folding
Simulates the wear and aging of an element (bracelet for example) |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Jewelry, Watchmaking |
Scratches
Simulates the scratch resistance of a component surface at different pencil lead hardnesses. Simulates the degradation of the aesthetics of watch cases and their accessories under the conditions of wear |
|
Standard: | ISO 15184, ISO 23160 |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Packaging / display, Leather goods, Jewelry, Watchmaking |
Peel strength
Allows the control of the behavior of a coating / surface finish by contact with different adhesive tapes |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Sand resistance rotating bezel
The middle part with rotating bezel is placed in a barrel with sand, then functionality check and torque measurement |
|
Standard: | Internal standard |
Equipment: | Coating wear |
Certification: | No |
Sectors: | Watchmaking |
Rotation of the rotating bezel
Simulates the wear and aging of the rotating movement of the bezel |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Watchmaking |
Drum fouling
Soil resistance test followed by a cleaning cycle |
|
Standard: | ISO 11378-2, ISO 105 A02 & ISO 105 A03 |
Equipment: | Coating wear |
Certification: | Yes |
Sectors: | Leather goods, Jewelry, Watchmaking |
Dye fastness on humid leather (Veslic test)
Control of the hold of the leather finish by linear friction with dry, wet and sweat |
|
Standard: | ISO 11640 / ISO 11641 |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Leather goods, Jewelry, Watchmaking |
Holding of reported elements
Measurement of the tensile / compressive strength of the added elements (by gluing / brazing / welding, etc.) |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Wear test according to EN-12472
Wear test applied to any coated part prior to nickel release test |
|
Standard: | EN 12472 |
Equipment: | Barrel developed for METALLO-TESTS |
Certification: | Yes |
Sectors: | Leather goods, Jewelry, Watchmaking |
Traction
Measures the breaking force (seals, bracelet, …) up to 5000 N |
|
Standard: | Internal standard |
Equipment: | JJTM 5000 |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Tensile – bending
Simulates the aging of the case / bracelet connection or bracelet construction in bending |
|
Standard: | internal |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Jewelry, Watchmaking |
Traction – torsion
Simulates the aging of a bracelet or a case/bracelet assembly by pulling/twisting |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Jewelry, Watchmaking |
Multidirectional abrasion wear
Simulates the wear and aging of an assembly (metal bracelet for example) |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Medical, Jewelry, Watchmaking |
Anti-reflective wear on glass
Range of tests to qualify the resistance to wear and aging of a surface treatment on glass (Anti-reflection) with control of the transmittance |
|
Standard: | ISO 2819 |
Certification: | No |
Sectors: | Watchmaking |
Loop wear (edge tinting fastness)
Simulates the wear and aging of the movement of the strand passing through a loop when putting on and taking off the watch |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Jewelry, Watchmaking |
Wear clasp / mobile element on box
Simulates the aging of the closing / opening functions of a clasp |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Jewelry, Watchmaking |
Passing wear
Simulates the wear and aging of the movement and the wear from the friction of the loops (moving and fixed) |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | No |
Sectors: | Jewelry, Watchmaking |
Tappet wear
Simulates the wear and aging of the pusher functions of a watch (Start – Stop – Reset) |
|
Standard: | Internal standard |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Jewelry, Watchmaking |
Handbag wear
Simulates component wear and aging with items of a hand bag |
|
Standard: | Internal standard |
Equipment: | Coating wear |
Certification: | No |
Sectors: | Jewelry, Watchmaking |
Turbula or Polyservice wear
Simulates the wear and aging of a component in contact with an abrasive mixture |
|
Standard: | ISO 23160, NIHS 96-22 |
Equipment: | Coating wear |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking |
Vibrations
Simulates wear and aging during vibration
Standard: | Internal standard | |
Equipment: |
|
|
Certification: | No | |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking |
Consulting, Contrôle, Homologations
Consulting
Soutien et gestion de projet et demande, suivi et mise en place d’actions correctives et conseil chez les clients |
|
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Certification
Boîtes, cadrans, Bracelets cuirs – polymères – métal, aiguilles, fermoir, boucle, packaging, display.
|
|
Sectors: | Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking |
REACH
REACH est un règlement européen régi par l’ECHA (European CHemicals Agency) basée à Helsinki. Il a été adopté pour mieux protéger la santé et l’environnement contre les risques liés aux substances chimiques. Ce règlement exige que tout produit chimique entrant en Europe soit enregistré dans le but de connaître à quelle fin il sera utilisé. |
|
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
RoHS
Restriction of the use of certain Hazardous Substances.
|
|
Equipment: | Shimadzu ICPE-9000 et Shimadzu GC-MS QP2010 Ultra |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Material characterisation
Water absorption / retention (leather)
Determination of water absorption and desorption by leather |
|
Standard: | ISO 2417 |
Equipment: | Kubelka & Vötsch VCL 4033MH |
Certification: | No |
Sectors: | Telephony, Packaging / Display, Leather goods, Jewelry, Watchmaking |
Adhesion
Adhesive tape or thermal shock resistance test |
|
Standard: | Internal standard / NIHS 96-50 |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Stainless steel analysis
Determination of chemical composition and/or inclusion research according to ISO 20160 methods M or K |
|
Standard: | DIN 50602 |
Equipment: | Optical microscope and scanning electron microscope Zeiss Sigma |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
EDX/EDS analysis (qualitative and semi-quantitative from Beryllium)
Qualitative and semi-quantitative analysis by EDX (Energy Dispersive X-ray Spectrometry) from beryllium |
|
Equipment: | Aztec Advanced Microanalysis |
Certification: | yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Brass analysis
Inclusion determination, grain size and chemical composition. |
|
Equipment: | Optical microscope and scanning electron microscope Zeiss Sigma |
Sectors: | Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking |
Polymer characterization
Rubber, plastic, glue, resin characterization of the structure |
|
Standard: | Internal standard |
Equipment: | Shimadzu IRPrestige-21 |
Certification: | No |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Coating adhesion control
Mechanical resistance check and adhesion of the coating by adhesive tape, thermal shock, folding, gridding |
|
Standard: | ISO 2819, ISO 3157, ISO 27874 & NIHS 96-50 |
Equipment: | Equipment developed by the laboratory |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Scanning Electron Microscope exam
Component examination and characterization |
|
Equipment: | Zeiss Sigma electronic microscope |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
Metallographic examination
Metallographic examination of materials with characterization of phases, inclusions and grain size |
|
Equipment: | Optical microscope |
Sectors: | Medical, Jewelry, Watchmaking, Metalworking |
Optical examination of inclusions
Search for inclusions according to DIN 50602 M or K methods |
|
Standard: | DIN50602 |
Equipment: | Optical microscope |
Certification: | Yes |
Sectors: | Medical, Jewelry, Watchmaking, Metalworking |
Grain index
Determination of grain size and index according to ASTM E-112 method |
|
Standard: | ASTM E-112 & ISO 643 |
Equipment: | Optical microscope |
Certification: | Yes |
Sectors: | Medical, Jewelry, Watchmaking, Metalworking |
Lab colorimetric measurement
Measurement of L*a*b parameters to assess color changes |
|
Standard: | ISO 12647 |
Equipment: | UV-2600 spectrometer with integrating sphere |
Certification: | No |
Sectors: | Medical, Jewelry, Watchmaking |
Vickers hardness measurement
Vickers micro-hardness measurement (50 g to 1 kg load) |
|
Standard: | ISO 6507-2 & ISO 4516 |
Equipment: | Emco DuraScan-80 |
Certification: | Yes |
Sectors: | Medical, Jewelry, Watchmaking, Metalworking |
MIM density measurement (density – image analysis)
Measurement and control of the density of a component by weighing and/or porosity rate on microsection |
|
Standard: | ASTM B 311-93 |
Equipment: | Ohaus Pioneer PA214 Analytical Balance |
Certification: | No |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
Schore A hardness measurement
Rubber/plastic hardness measurement |
|
Standard: | ISO 7619-1 |
Equipment: | Wolpert Amsler Testor |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Optical and SEM thickness measurements
Measurement of coating thickness on cut |
|
Standard: | ISO 1463 |
Equipment: | Optical microscope and scanning electron microscope Zeiss Sigma |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
Bending, punching
Coating resistance test on the surface of the parts |
|
Standard: | NF 80-772 |
Equipment: | Stem + internal tooling |
Certification: | No |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
Coating preparation
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Surface contamination research
Equipment: | Microanalyze Oxford Aztec Advenced |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Test de transport sur emballage
Chocs horizontaux
Situation of horizontal shocks |
|
Standard: | NF H00.047 / ISO 1413 |
Equipment: | Pendulum sheep |
Certification: | Yes |
Sectors: | Logistic, Watchmaking, Metalwork, Jewelry, Leather goods, Packaging/display, Medical, Telephony, Toys, Glass making, micro electronics, Writing instruments, Environment |
Chocs verticaux par chute libre
Simulation of free fall of the object |
|
Standard: | ISO 2248 / ISO 1413 |
Equipment: | Free fall |
Certification: | No |
Sectors: | Logistic, Watchmaking, Metalwork, Jewelry, Leather goods, Packaging/display, Medical, Telephony, Toys, Glass making, micro electronics, Writing instruments, Environment |
Test de conditions climatiques
Simulates climatic conditions during transport |
|
Standard: | ISO 23160 |
Equipment: | Climatic chamber |
Certification: | Yes |
Sectors: | Logistic, Watchmaking, Metalwork, Jewelry, Leather goods, Packaging/display, Medical, Telephony, Toys, Glass making, micro electronics, Writing instruments, Environment |
Vibrations à basses fréquences fixes
Situation of vibration at low frequencies of the object |
|
Standard: | NF H00.043 |
Equipment: | equipment developed by the lab |
Certification: | No |
Sectors: | Logistic, Watchmaking, Metalwork, Jewelry, Leather goods, Packaging/display, Medical, Telephony, Toys, Glass making, micro electronics, Writing instruments, Environment |
Equipement
Bain à ultrason (us)
Réglage de la température entre 30°C et 80°C |
|
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Bain agité thermorégulé
Réglage de la température entre 20°C et 99°C |
|
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Dynamomètres et couple-mètre
Appareils Mecmesin |
|
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Enceintes climatiques ATT DY 250 et DY 250+UV
Chambre climatique chaleur (-80°C à +180°C) et humidité (0% à 100%) fixées, rayonnement solaire |
|
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Enceintes de pulvérisation
Chambres de corrosion en aérosol ( brouillard salin / sueur synthétique / selon demande) |
|
Certification: | Yes |
Sectors: | Jewelry, Watchmaking, Metalworking |
GC-MS avec détecteur EI et GC-MS avec détecteur NCI + Headspace
Cette machine permet de doser la chromatographie en phase gazeuse avec MS, permet de détecter des traces de produits chimiques dans des solvants organiques, tels que des phtalates, fragrances, …
|
|
Equipment: | Shimadzu GC-MS QP2010 Ultra et Shimadzu GC-MS QP2010 Ultra + HS20 |
Certification: | Yes |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
Machine de traction capacité (1N à 5kN)
Mesure de la force de résistance à la traction / compression |
|
Standard: | Internal standard |
Equipment: | JJTM 5000 |
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Mariotmètre et cuves à surpression d’eau pour contrôle étanchéité (max. 100 bar / 1000 m)
Contrôle l’étanchéité de la pièce |
|
Standard: | ISO 22810 / ISO 6425 |
Certification: | Yes |
Sectors: | Watchmaking |
Matériel de préparation et d’enrobage pour la métallographie
Presse à enrober et lapidaire pour la préparation des coupes métallographiques avec possibilité de métallisation or et cuivrage électrochimique |
|
Certification: | No |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Micro-duromètre (HV 0,01 à 10.0)
Mesure de la micro-dureté Vickers (charge de 10 g à 10 kg) |
|
Standard: | ISO 6507-2 & ISO 4516 |
Equipment: | Emco DuraScan-80 |
Certification: | Yes |
Sectors: | Medical, Leather goods, Jewelry, Watchmaking, Metalworking |
Microscope électronique à balayage à effet de champs ( FEG ).
Appareil très puissant, avec résolution au nanomètre.
|
Microscopie optique
Mesure sur coupe ou composant au microscope optique |
|
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Spectromètre FTIR
Fourier Transform InfraRed Spectrometer avec ATR (cellules Silver et Ge) |
|
Equipment: | Shimadzu IRPrestige-21 |
Certification: | No |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |
ICP-OES Spectrometer
Cette machine haut de gamme permet un dosage des traces de la plupart des éléments du tableau prériodique en milieu aqueux. Son seuil de détection atteint le ppb, voire ppt en fonction de la matrice. |
|
Equipment: | Shimadzu ICPE-9000 |
Certification: | Yes |
Sectors: | Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking |
Spectromètre UV-VIS
UltraViolet VISible spectrometer avec sphère d’intégration |
|
Equipment: | Shimadzu UV-2600 |
Certification: | No |
Sectors: | Medical, Packaging / display, Leather goods, Jewelry, Watchmaking |