Skip to main content

2-MBT (2-Mercaptobenzothiazole)
2-MBT dosage
n° CAS 149-30-4
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: No
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
4,4-Méthylènedianiline
Dosage of 4,4-Methylene dianiline (hardener amine listed under restricted amines)

n° CAS 101-77-9
Standard: ISO 17234 et EN 14362-1
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
Alkylphénols
Dosage of alkylphenols and their ethoxylates
Standard: ISO 18218-1 and internal extraction
Equipment: Shimadzu HPLC Nexera
Certification: No
Sectors: Watchmaking, Jewelry, Leather goods, Packaging / Displays
ICP-OES Analysis
Dosage of metals by photon emission at its wavelengths (majority of the elements of the periodic table except rare gases, halogens (except I), actinides (except Th and U), H, C, N, O, Tc, Pm, Po , At, Fr, Ra)
Equipment: Shimadzu ICPE-9000
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
GC-MS Analysis
Dosage of organic substances by column separation (GC) and characterization by mass spectrometer (MS)
Equipment: Shimadzu GC-MS QP2010 Ultra
Sectors: Medical, Packaging / display, Leather goods, Jewelry, Watchmaking
Analyse par spectrométrie FTIR avec ATR (Silver gate et Ge)
Polymer characterization
Equipment: Shimadzu IRPrestige-21
Sectors: Packaging / display, Leather goods, Jewelry, Watchmaking
REACH & RoHS Analysis
Dosage of restricted or prohibited substances according to REACH and RoHS legislation, but also such as: Japanese law 112, California Proposition 65, ORRChim, US CPSA, GB China
Standard: Substance dependent
Equipment: Depends on substance
Certification: Yes
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
Anthracene
Dosage of Anthracene (SVHC, REACH)
n° CAS 120-12-7
Standard: AfPS GS 2014:01 PAK
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Watchmaking, Metallurgy, Jewelry, Leather Goods, Packaging / Display, Medical
Michler's base and Michler's ketone (MB and MK)
Dosage of MB and MK (SVHC REACH)

BM n°CAS 101-61-1

CM n°CAS 90-94-8
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking
Chlorophenols
Detection of chlorophenols (PCP, TriCP and TeCP (ORRChim)
PCP n°CAS 87-86-5
TriCP n°CAS 88-06-2
TeCP n°CAS 58-90-2 et 935-95-5
Standard: EN ISO 17070
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Packaging / display, Leather goods, Jewelry, Watchmaking
Soluble chrome
Extractable total chromium dosage
Standard: ISO 105-E04
Equipment: Shimadzu ICPE-9000
Certification: No
Sectors: Medical, Packaging / display, Leather goods, Jewelry, Watchmaking
Chrome VI
Hexavalent chromium (Chromium VI) dosage in leather
Standard: EN ISO 17075-1
Equipment: Shimadzu UV-2600
Certification: Yes
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
Allergenic and carcinogenic disperse dyes
Dosage of allergenic or carcinogenic disperse dyes

Subcontracted test
Standard: DIN 54231
Equipment: Shimadzu HPLC Nexera
Certification: Yes
Sectors: Medical, Leather goods, Jewelry, Watchmaking
Azo dyes / Aromatic amines
Determination of restricted aromatic amines resulting from the reductive cleavage of azo dyes (REACH)
Standard: ISO 17234, EN 14362-1 et EN 14362-3
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Medical, Packaging / display, Leather goods, Jewelry, Watchmaking
Fluorine compounds
Detection of fluorinated compounds (SVHC, REACH)

Analyse sous-traitée
Standard: CEN/TS 15968
Equipment: Shimadzu HPLC Nexera
Certification: Yes
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking
DMF (N,N-Diméthylformamide)
Determination of DMF (SVHC REACH)

n°CAS 68-12-2
Standard: ISO 16189
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Watchmaking, Jewelry, Leather goods, Packaging / Display, Medical, Telephony
DMFu (Diméthylfumarate)
Determination of DMFu (Annex XVII REACH)
n°CAS 624-49-7
Standard: ISO 16186
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking
DMG (Dimethylglyoxime)
Méthode de contrôle qualitative pour la libération du nickel par frottis
Standard: PR EN 12471
Equipment: Kit DMG
Certification: No
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
Dosage of elements in alloys
Dosage of alloying elements
Standard: NF EN 62321, EN 10351 & EPA Method 3052B
Equipment: Shimadzu ICPE-9000
Certification: Yes
Sectors: Medical, Leather goods, Jewelry, Watchmaking, Metalworking
EGDMA (Ethylene Glycol Dimethacrylate)
Determination of EGDMA (H317)
n°CAS 97-90-5
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking
Formamide
Determination of Formamide (SVHC, REACH)
n°CAS 75-12-7
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra et Shimadzu GC-MS QP2010 Ultra + HS20
Certification: No
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking
Formaldehyde
Formaldehyde testing, Japanese Law 112 and California Proposition 65

n° CAS 50-00-0
Standard: ISO 17226-1, ISO 17226-2 et ISO 14184-1
Equipment: Shimadzu HPLC Nexera
Certification: Yes
Sectors: Medical, Packaging / display, Leather goods, Jewelry, Watchmaking
HAP (Hydrocarbures Aromatiques Polycycliques)
Dosage of PAHs according to US-EPA and Annex XVII, REACH
Standard: AfPS GS 2014:01 PAK et ISO 18287
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
HBCDD (Hexabromocyclododecane)
Determination of HBCDD – all isomers (Annex XIV REACH)
n°CAS 3194-55-6
Standard: ISO 17881-1
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Medical, Packaging / display, Leather goods, Jewelry, Watchmaking
Oils
Composition of movement oils
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: No
Sectors: Medical, Watchmaking
Imidazolidine-2-thione
Determination of Imidazolidine-2-thione (vulcanization accelerator, SVHC, REACH)
n°CAS 96-45-7
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: No
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking
Isocyanates
Dosage of isocyanates (H317)
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010
Certification: No
Sectors: Watchmaking, Jewelry
Nickel release
Determination of the weekly released nickel quantity per unit of surface in synthetic sweat (Annex XVII, REACH), with or without prior wear simulation according to EN 12472.

n°CAS 7440-02-0
Standard: EN 1811 et EN 12472
Equipment: Shimadzu ICPE-9000
Certification: Yes
Sectors: Telephony, Medical, Jewelry, Watchmaking, Metalworking
Metals and their salts
Metal quantification (SVHC, RoHS 2, and California Proposition 65)
Standard: EN 62321, ISO 17072-2, EN 10351 et EPA Method 3052B
Equipment: Shimadzu ICPE-9000
Certification: Yes
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking, Telephony
NMP (N-Methyl-2-Pyrrolidone)
Dosage NMP (SVHC REACH)
n°CAS 872-50-4
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking
Organotin chemistry
Dosage of organotins (Japanese law 112, REACH and ORRChim)
Standard: ISO/TS 16179
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Packaging / display, Leather goods, Jewelry, Watchmaking
Para-Phenylenediamine (PPD) and N-Isopropyl-N’-phenyl-p-phenylenediamine (IPPD)
Determination of PPD (allergenic dye present in plastics/rubbers)
n°CAS 106-50-3
Determination of IPPD (allergenic antioxidant for plastics/rubbers)
n°CAS 101-72-4
Standard: Norme interne et EN 14362-1
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: No
Sectors: Leather goods, Jewelry, Watchmaking
PBB and PBDE (Polybrominated Biphenyls and Polybrominated Diphenyl Ethers)
Determination of PBB and PBDE (flame retardants, RoHS and REACH)
Standard: ISO 17881 et EN 62321
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
SCCP (Short-Chain Chlorinated Paraffins, C10-C13)
Determination of the presence of SCCP (organic pollutants) (Regulation (EC) No 850/2004, update No 519/2012)
n°CAS 85535-84-8
Standard: ISO_DIS 18219
Equipment: Shimadzu GC-MS-NCI QP2010 Ultra
Certification: Yes
Sectors: Packaging / display, Leather goods, Jewelry, Watchmaking
pH
Determination of pH value (acidity level)
Standard: EN ISO 4045 (cuir) et ISO 3071 (textile)
Equipment: pH meter
Certification: Yes
Sectors: Packaging / display, Leather goods, Jewelry, Watchmaking
Phthalates
Dosage of phthalates (SVHC, CPSA)
Standard: ISO/TS 16181 (cuir/caoutchouc) et ISO 14389 (textile)
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Packaging / display, Leather goods, Jewelry, Watchmaking
PTBP (p-tert-Butylphenol)
Dosage du PTBP
n° CAS 98-54-4
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Leather goods, Jewelry, Watchmaking
PTOP (p-tert-Octylphenol or 4-tert-Octylphenol) (H315)
Dosage du PTOP (SVHC REACH)
n° CAS 140-66-9
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking
 
Allergen screening
Screening to detect the main allergens present in articles.
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010
Certification: No
Sectors: Medical, Watchmaking, Jewelry, Telephony
Screening REACH
Screening to detect SVHC (REACH) substances present in articles.
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010
Certification: No
Sectors: Watchmaking, Jewelry, Leather goods, Packaging / Display, Medical, Telephony
Sulfur and Carbon
Determination of sulfur and carbon
Standard: ISO 15350
Equipment: Combustion avec détecteur infrarouge
Certification: No
Sectors: Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
 
UV stabilizers
Dosage of the following UV stabilizers:
UV 320 (n° CAS 3846-71-7)
UV 327 (n° CAS 3864-99-1)
UV 328 (n° CAS 25973-55-1)
UV 350 (n° CAS 36437-37-3)

Standard: Internal standard
Equipment: Shimadzu GC-MS QP 2010 Ultra
Certification: No
Sectors: Watchmaking, Jewelry, Packaging / Display
TCEP (Tris(2-chloroethyl) phosphate)
Determination of TCEP (SVHC, REACH)
n°CAS 115-96-8
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Telephony, Packaging / Display, Leather goods, Jewelry, Watchmaking
TGIC and beta-TGIC (Triglycidyl isocyanurate)
Determination of TGIC and beta-TGIC (SVHC REACH)
TGIC n°CAS 2451-62-9
beta-TGIC n°CAS 59653-74-6
Standard: Internal standard
Equipment: Shimadzu GC-MS QP2010 Ultra
Certification: Yes
Sectors: Telephony, Medical, Packaging / Display, Leather goods, Jewelry, Watchmaking, Metalworking
Leather aging before Cr VI analysis
Leather aging before chromium VI analysis
Standard: ISO 17075-3
Equipment: Steamroom
Certification: No
Sectors: Packaging / Display, Leather goods, Jewelry, Metalworking, Watchmaking